WE CAN DO CONFORMANCE TEST FOR THESE FLAGS : INDONESIA, ANTIGUA AND BARBUDA, AUSTRALIA, AUSTRIA, BAHAMAS, BAHRAIN, BARBADOS, BELGIUM, BELIZE, BERMUDA, CANADA, CAYMAN ISLANDS, CROATIA, CYPRUS, DENMARK, DOMINICA, ESTONIA, FAROE ISLANDS, FINLAND, GERMANY, GIBRALTAR, GREECE, HONG KONG, IRELAND, ISLE OF MAN, JAMAICA, JORDAN, LATVIA, LIBERIA, LITHUANIA, LUXEMBOURG, MADEIRA (REGISTRY), MALTA, MALAYSIA, MARSHALL ISLANDS, NETHERLANDS ANTILLES, NEW ZEALAND, NORWAY, PAKISTAN, PANAMA, PAPUA NEW GUINE, PORTUGAL, QATAR, ROMANIA, ST.KITTS AND NEVIS, ST.VINCENT AND THE GRENADINES, THE SEYCHELLES, THAILAND, SIERRA LEONE, SINGAPORE, SLOVAK REPUBLIC, SWEDEN, SWITZERLAND, TURKEY, UNITED ARAB EMIRATES, UNITED KINGDOM.
VTS
FLM
PRT
PST
LRIT
OASE
PIDS
 
Overview
General Description
Table Picture

MEMBER LOGIN
info | forget password?

 
FUEL / LIQUID MONITORING - GENERAL DESCRIPTION
 

The fuel monitoring systems primary function is to ease the Fleet Managers work. Automating the system reduces human interferences thus increasing the accuracy. The primary components used will be Mass Flow meters with an accuracy level of 0.3 %. These flow meters are used as an array to monitor the fuel from the day tank that flows into the Main Engine and the Auxiliary Engine.

With this array of Flow meters in place, the rest of the work is done within the system to do the calculations to give a better picture of the fuel usage during the vessel is on voyage, this reducing the need for the vessel operators to be physically present to curb pilfering of fuel. This system allows the Shipowner/operators to monitor the fuel consumption by web application. Data from the fleet will be send via Inmarsat Satellite, with worldwide coverage.


Reflex mode
Two ultrasonic transducers (sensors) are mounted on the same side of the pipe at an angle to the pipe axis.
 
A,BTransmitter and receiver
LDistance between sensors
vmaverage flow velocity of liquid
vAB (vBA)Propagation speed (transie time) of sound waves from point A to point B, and B to point A

Diagonal mode
Two ultrasonic transducers (sensors) are mounted on opposite sidea of the pipe at angle to the pipe axis.
 

 Features
  • User friendly can be used as wall mounted version
  • Low cost and
  • Clamp-on

For Pipe size
A sensors: *13mm to 89 mm
B sensors: 90 mm to 1000 mm
C sensors: 300 mm to 2000 mm
D sensors: 1000 mm to 5000 mm

*Pipe size ,50mm: Liquid must be homogeneous, without solid / air bubbles antrainmnet.

Temperature rangeA,B,C: -20C to +125C
Temperature rangeD: -20C to +70C
DisplayVolumetric flow units: m, gallons, liters
Velocity unitsm.s, ft/s
Signal output4-20 mA into 750 opto isolated
PulseMax 1 pulse per second (user definable scaling)
Analogue output2 off 0-16, 0-20 or 4-20 mA
Opto isolated with user definable scaling
Power110V-240 VAC or 24 VDC

 

 